Service Membership Plans in Fort Smith, Fayetteville, Rogers, AR, and Surrounding Areas
Premium PLAN
$160.00 One Unit / additional unit $80.00 each
Monthly payment plan only $14.00
Furnace Tune-up
- Test Capacitors
- Inspect Ducts or obvious defects
- Clean blower wheel
- Record blower motor amp draw lubricate if applicable
- Replace filter ( customer provided at visit)
- Check thermostat and calibrate if possible
- Inspect gas and flue connections
- Check high limit
- Clean burners
- Inspect heat exchanger for cracks or sooting
- Check and set gas pressure
- Check all electrical connections
- Test all safeties
- Check electrical heating elements and circuits
- Check refrigerant pressures
- Check reversing valve
- Inspect all IAQ products
- Check electrical connections in outdoor unit ( Heat pump)
- Record compressor motor AMP draw (Heat pump)
- Record condenser motor AMP draw ( Heat pump)
- Inspect cooling coils (where readily accessible Heat pump)
A/C – Heat pump Tune-Up
- Test capacitors
- Check electrical connections in outdoor unit
- Inspect all IAQ produces
- Check reversing valve
- Check refrigerant pressures subcooling and superheat
- Compare to factory setting
- Test all safeties in UOT door unit
- Replace filter (customer supplied at time of visit)
- Record blower motor AMP draw lubricate if applicable
- Record compressor motor AMP draw
- Record condenser motor AMP draw
- Thoroughly wash condenser coil
Premium PLUS
$240.00 Per Unit
Monthly payment plan Only $21.00
Furnace Tune-up
- Test Capacitors
- Inspect Ducts or obvious defects
- Clean blower wheel
- Record blower motor amp draw lubricate if applicable
- Replace filter ( customer provided at visit)
- Check thermostat and calibrate if possible
- Inspect gas and flue connections
- Check high limit
- Clean burners
- Inspect heat exchanger for cracks or sooting
- Check and set gas pressure
- Check all electrical connections
- Test all safeties
- Check electrical heating elements and circuits
- Check refrigerant pressures
- Check reversing valve
- Inspect all IAQ products
- Check electrical connections in outdoor unit ( Heat pump)
- Record compressor motor AMP draw (Heat pump)
- Record condenser motor AMP draw ( Heat pump)
- Inspect cooling coils (where readily accessible Heat pump
Includes a complete Evaluation of your system performance with a printed report detailing your system total capacity gathered by the I-Manifold
Example:
- United Rated 36,000 BTU
- Unit Preforming 32,000 BTU
A/C – Heat pump Tune-Up
- Test capacitors
- Check electrical connections in outdoor unit
- Inspect all IAQ produces
- Check reversing valve
- Check refrigerant pressures sub cooling and superheat
- Compare to factory setting
- Test all safeties in UCT door unit
- Replace filter ( customer supplied at time of visit)
- Record blower motor AMP draw lubricate if applicable
- Record compressor motor AMP draw
- Record condenser motor AMP draw
- Thoroughly wash condenser coil